Automatic Fire Suppression for Port and Terminal Equipment

A fire on a piece of container handling equipment rarely starts where anyone can see it. On an RTG crane it's often the diesel genset or the electrical cabinet running the drive system, thirty feet up in a machine straddling a container row. On a straddle carrier or a reach stacker it's the engine compartment, working a duty cycle all day in salt air. On a terminal tractor shuttling boxes between the crane and the yard, it's an engine bay running back to back moves with barely a break between them. By the time smoke is visible from the ground or the cab, the compartment it started in is already fully involved, and the equipment is often high off the ground or deep in a container stack where a handheld extinguisher can't reach it fast.

BlazeCut protects that compartment automatically, whether it's an RTG's electrical cabinet, a straddle carrier's engine bay, or a terminal tractor's hydraulic system, with no operator, no wiring, and no control panel required to catch it in time.

How Does The T-Series Work?

A diagram of the t-series automatic fire suppression system from BlazeCut

The BlazeCut tube is the detector and the extinguisher in a single sealed unit, installed directly inside the compartment it protects. Every point along the tube senses heat continuously.

When any point reaches the actuation threshold, the tube ruptures at that exact location and discharges the agent directly onto the ignition source, whether that's a genset on a crane or an engine bay on a yard tractor, before it spreads to the rest of the machine.

No power required. The T-Series operates independently of any electrical supply, which matters on equipment that runs unattended stretches at height, deep in a stack, or on a night shift with a smaller crew on the ground.

Sealed and rated for harsh duty. Stainless steel fittings and a tube rated for a service life of up to 10 years, with no scheduled maintenance requirement, built for equipment that runs in salt air, vibration, and around-the-clock duty cycles.

Sized to the equipment. Available in lengths from 10 inches to 26 feet, covering roughly 3.5 to 141 cubic feet, so the same product line fits a terminal tractor's engine bay, a straddle carrier's hydraulic compartment, or an RTG's electrical cabinet.


Typical Installation Points on Port and Terminal Equipment

Cranes & Gantry Equipment

  • Diesel genset compartments on RTG cranes
  • Electrical and drive control cabinets on RTGs and rail-mounted gantry cranes
  • Engine and hydraulic compartments on mobile harbour cranes

Yard & Container Handling Equipment

  • Engine compartments on straddle carriers, reach stackers, and top handlers
  • Hydraulic pump and valve compartments on reach stackers and container handlers
  • Engine bays on terminal tractors and yard hostlers

Electrical & Battery Systems

  • Electrical control cabinets on electric and hybrid RTGs and yard equipment
  • Battery compartments on electric terminal tractors and container handlers
  • Spreader and control electronics enclosures

Protecting Your Terminal, Your Throughput, & Your Crews

A single system protects one machine. A terminal-wide rollout protects the throughput commitment behind every crane move and every truck turn. We work directly with terminal operators, stevedoring companies, and port authorities to size systems across a full equipment fleet and structure pricing for terminal-wide and multi-berth deployments.

Contact Dalton at dalton@blazecutusa.com to scope a terminal or fleet-wide deployment.

  • MONEY

    A fire contained inside one engine bay or electrical cabinet is a repair and an insurance claim. A fire that spreads on an RTG or a straddle carrier can take out a machine that costs millions to replace, on top of the containers and cargo near it. Terminal-wide suppression turns an unpredictable loss into a fixed, budgeted cost.

  • DOWNTIME

    A fire suppressed inside the compartment it started in is a short repair. A fire that spreads on a crane or a yard machine takes that unit out of rotation for weeks, and one fewer RTG or straddle carrier on a busy berth backs up every truck and vessel behind it. Suppression at the source is what keeps one hot genset from becoming a terminal-wide bottleneck.

  • TIME

    No one has to notice the smoke and reach a machine that may be thirty feet up or deep in a container stack, especially on a night shift with fewer eyes on the yard. The system is already inside the compartment, sensing heat continuously, and it discharges the moment it detects ignition, whether or not anyone is close enough to see it start.

  • SAFETY

    Nobody has to climb up to a smoking RTG cabinet or approach a burning engine bay on equipment working around live crane operations and moving traffic. The system suppresses the fire before it grows, which means less exposure for crews working the yard around it.

  • EFFORT

    There is no control panel to program, no wiring to run, and no scheduled maintenance to track. The T-Series is installed once, inside the compartment it protects, and it works independently of any electrical supply for up to 10 years, on equipment that runs around the clock and is expensive to pull out of rotation for inspection.

  • PEACE OF MIND

    Once it is installed, it works whether the machine is working a double shift on a busy berth or sitting overnight in the yard. A terminal with suppression built into every high-risk compartment is a terminal where one hot component doesn't turn into a lost crane and a closed lane.

1 of 6

  • LPS 1666, LPCB approved. LPCB (the Loss Prevention Certification Board, part of BRE Global in the UK) is one of the most established third-party fire testing and certification bodies internationally, and its approval is widely recognized and accepted by insurers and AHJs.
  • CE Mark. Certifies the system meets applicable EU health, safety, and performance requirements, independently verified.
  • Independently performance tested at an accredited testing institute, Strojírenský zkušební ústav, s.p., in the Czech Republic.
  • Designed in accordance with NFPA 2001. This is the specific US standard governing clean agent extinguishing systems.
  • Manufactured at an ISO 9001 and ISO 14001 certified facility, also certified to AQAP 2110. AQAP 2110 is a NATO quality assurance standard for design, development, and production.

On port and maritime-specific requirements: Port facilities often layer their own terminal safety programs, insurance requirements, and, for equipment used in maritime service, potential classification society or flag-state considerations on top of general fire code. Confirm your terminal's specific requirement with your safety director, insurer, or the applicable authority before treating this as a compliance checklist.

Manage A Terminal Or Are You Looking At Procurement For A Contract?

We work directly with terminal operators, stevedoring companies, and port authorities to fulfill their fire suppression needs. Simply email Dalton: dalton@blazecutusa.com for purchasing options or volume discounts!


FAQ

What is the BlazeCut T Series fire suppression system?

The BlazeCut T Series is an automatic, self-contained fire suppression system. It requires no wiring, no external power supply, and no separate storage cylinder. A heat-sensitive tube filled with pressurized FK-5-1-12 clean agent runs through the protected enclosure and acts as both the detection device and the agent storage container. When a fire develops, the tube melts at the hottest point and discharges the agent directly onto the fire source. The entire process is automatic and requires no human intervention.

How does the system detect a fire?

The BlazeCut tube continuously monitors the temperature of the entire space it runs through. When heat from a developing fire causes the tube to reach its actuation temperature, the tube ruptures at that exact location, right at the fire source, and releases the agent. There are no sensors, control boards, or wiring required for the standard T Series to activate.

Does the BlazeCut T Series need electricity to work?

No. The standard T Series operates completely independently of any power supply, 24 hours a day. This makes it well suited for protecting unoccupied spaces, equipment running after hours, engine compartments, and electrical enclosures where running wires is impractical or impossible. The optional pressure switch version can connect to an external signaling device if notification is needed, but the suppression system itself still does not require power to activate.

What extinguishing agent does BlazeCut USA carry?

BlazeCut USA carries the T Series charged exclusively with FK-5-1-12, also known by its chemical name Perfluoro(2-Methyl-3-Pentanone) and formerly marketed as Novec 1230. CAS number 756-13-8. It is a clean gaseous agent that is electrically non-conductive, non-corrosive, and leaves zero residue after discharge. It has zero ozone depletion potential and a global warming potential of 1.00 relative to CO2. FK-5-1-12 is listed in the US Toxic Substances Control Act (TSCA) inventory and is suitable for Class A, B, C, and electrical fire protection.

Does FK-5-1-12 leave a mess after the system fires?

No. FK-5-1-12 leaves absolutely no residue. There is no powder, no foam, and no water damage to deal with after the system activates. This is one of the main reasons it is the right choice for protecting electronics, server equipment, electrical control panels, and other sensitive equipment where a traditional extinguisher would cause serious secondary damage on top of whatever the fire already did.

Is FK-5-1-12 safe for people?

FK-5-1-12 is not classified as hazardous under standard conditions of use. Acute toxicity testing shows an oral and dermal LD50 greater than 2,000 mg/kg in rats and an inhalation LC50 greater than 1,227 mg/L over a 4-hour period. It is not listed as a carcinogen by NTP, IARC, or OSHA and has not been found to be mutagenic or toxic to reproduction. Standard precautions apply: avoid breathing vapors in an enclosed space at the time of discharge and ventilate the area before re-entry.

How difficult is it to install the BlazeCut T Series?

Installation is straightforward. The tube is secured inside the protected enclosure using heavy-duty cable ties or optional one-hole mounting clamps. No drilling, welding, or vehicle modifications are required. Each retail package includes the system, a user manual, cable ties, and warning labels. Most installations in engine compartments and electrical enclosures take under an hour.

Do I need a licensed technician to install it?

For most T Series applications, including engine compartments, electrical enclosures, small vehicles, and boats, installation does not require specialized tools or licensing. For fleet-wide deployments or larger commercial installations, we recommend working with an authorized BlazeCut dealer who can ensure proper sizing and placement. Visit our [Find a Dealer] page to locate one near you.

How do I figure out what size system I need?

System sizing is based on the volume of the enclosure being protected. Measure the width, height, and depth of the space in feet or meters to calculate the total volume. The smallest T Series option protects up to 3.18 cubic feet, and coverage scales up from there through the largest option, which protects up to 96.41 cubic feet for electrical fire applications and 73.45 cubic feet for engine fire applications. Coverage volumes are calculated at an ambient temperature of 68°F (20°C). If you are unsure which model is right for your application, email Dalton@blazecutusa.com and we can help you work through it.

What certifications does the BlazeCut T Series hold?

The BlazeCut T Series (6mm and 8mm BlazeTube configurations) is certified to LPS 1666 and carries CE approval. Systems have been independently performance tested at an accredited testing institute, Strojírenský zkušební ústav, s.p., in the Czech Republic, and are designed in accordance with NFPA 2001, the Standard on Clean Agent Fire Extinguishing Systems.

Is the BlazeCut T Series compliant with NFPA standards?

The T Series is designed in accordance with NFPA 2001, the Standard on Clean Agent Fire Extinguishing Systems. For specific compliance questions related to your facility, equipment, or local authority having jurisdiction (AHJ), we recommend consulting your AHJ directly or contacting us for guidance.

Is BlazeCut approved for the US market?

Yes. BlazeCut USA is the exclusive US importer and master distributor of BlazeCut fire suppression systems. The T Series is certified to LPS 1666 and CE approved, and the FK-5-1-12 agent is listed in the US TSCA inventory.

Can it protect an electric forklift or lithium battery compartment?

BlazeCut T Series systems can be deployed in the electrical and battery enclosures of electric forklifts and other electric-powered equipment. Lithium battery fires present specific suppression challenges, and the right system configuration depends on the enclosure size and layout. Email Dalton@blazecutusa.com to discuss the right setup for your fleet.

I am a distributor or catalog company. How do I carry BlazeCut?

BlazeCut USA is actively building its wholesale and dealer network across the country. If you are an industrial distributor, safety equipment supplier, or catalog company interested in stocking BlazeCut T Series systems, fill out the [Wholesale Partner Application] on our website or email Dalton@blazecutusa.com to start a conversation.

I manage a fleet or facility and need multiple units. Can I get volume pricing?

Yes. BlazeCut USA works with fleet managers, facilities teams, OEM manufacturers, and EHS departments to configure fire suppression programs across larger equipment inventories. Email Dalton@blazecutusa.com with details about your fleet or facility and we will connect you with the right resources.